By investing on Eseway Digital Hardness Tester EW-3000, you can simplify hardness measurement of both Brinell scale and Vicker scale. Eseway Digital Hardness Tester EW-3000 is devised ready-to-test digitally with closed loop controlled from a load cell system to measure toughness of a material and the maximum amount of energy it can absorb before fracturing.
Eseway Digital Hardness Tester EW-3000 provide innovative approach in streamlining your application within its loads 30kgf - 3000kgf. The indentation hardness of materials can be characterized through the scale of penetration of an indenter, loaded on a material test-piece. Conversion to either hardness scales and real-time statistics can also be done. This instruments also offered with INV-Impression system which includes: high performance PC- based camera indent measuring system, automatic measurement of the indent on the LCD screen.
When doing the hardness tests, the minimum distance between indentations and the distance from the indentation to the edge of the specimen must be taken into account to avoid interaction between the work-hardened regions and effects of the edge. These minimum distances are oftenly distinctive for ISO 6507-1 and ASTM E384 standards. Hence, to minimize the risk of human error in testing, the connectivity for data output via RS-232 is needed to allow you review those data directly or simply store, file, handle images on the PC for future reference.
Overall, Eseway Digital Hardness Tester EW-3000 is versatile and reasonably priced. Currently, this intrument is widely used by fabricators in defense industry, tool-making, optics, petrology and mineral, aerospace engineering. However, if you are looking for a basic Brinell tester, you migth want to consider CV instruments CV-3000LDB Hardness Tester.
Eseway Digital Hardness Tester EW-3000 Features:
Delivered On Stock Unit:
Optional accessories:
CV instruments Brinell Hardness Tester CV-3000LDB Ordering Guide:
Notes: When quoting a Brinell hardness number (BHN or more commonly HB), the conditions of the test used to obtain the number must be specified. The standard format for specifying tests can be seen in the example "HBW 10/3000". "HBW" means that a tungsten carbide (from the chemical symbol for tungsten or from the Swedish/German name for tungsten, "Wolfram") ball indenter was used, as opposed to "HBS", which means a hardened steel ball. The "10" is the ball diameter in millimeters. The "3000" is the force in kilograms force. Be advised to get the suitable instruments on your application by simply send your inquiry to us |
Brinell scale HB | 31.25, 62.5, 100, 125, 187.5, 250, 500, 750, 1000, 1500, 3000kgf |
Vickers HV | 30, 40, 50, 60, 80, 100, 120kgf |
Ball indenters | 10, 5, 2.5, 1mm |
Test force selection | Electronic, closed loop, load cell, force feedback system, indication in kgf or N |
Test procedure | Automatic, loading/dwell/unloading |
Loading speed | Variable, depending on load application |
Test force accuracy | < 1% full range |
User display | Diameter of indent, length of diagonals, hardness value, converted value, test force, online statistics |
Display resolution | 0.1 HB, HV |
Hardness conversion | Rockwell, Vickers, Brinell, Leeb & Tensile 2 scales simultaneously |
Standardisation | N, ISO 6507, EN ISO 6506, ASTM E-10-08, ASTM E-92 |
Statistics | Total tests, max, min, average, range, standard deviation, all in real time after each test |
Control panel | Start test, stop test, dwell time, print, clear, menu operation for date, time, scale and load settings, language |
Firmware | German, English, French (standard) |
Memory | Large memory for testing results |
Data output | RS-232, Bi-Directional |
Loading mechanism | Fully automatic, closed loop, force feedback, loading, dwell, unloading |
Dwell time setting | Default 10 seconds, user defined 1 to 99 seconds |
Eyepiece microscope | Analogue or optional bright dual line filar |
Vertical capacity | 220mm (450mm XL model) |
Horizontal capacity | 135mm (250mm XL model) from center-line |
Humidity | 10% to 90% non condensing |
Machine weight | 130kg (160kg XL model) |
Power requirements | 100VAC to 240VAC, 50/60Hz, single phase |
Power consumption | 390W |
Brinell scale HB | 31.25, 62.5, 100, 125, 187.5, 250, 500, 750, 1000, 1500, 3000kgf |
Vickers HV | 30, 40, 50, 60, 80, 100, 120kgf |
Ball indenters | 10, 5, 2.5, 1mm |
Test force selection | Electronic, closed loop, load cell, force feedback system, indication in kgf or N |
Test procedure | Automatic, loading/dwell/unloading |
Loading speed | Variable, depending on load application |
Test force accuracy | < 1% full range |
User display | Diameter of indent, length of diagonals, hardness value, converted value, test force, online statistics |
Display resolution | 0.1 HB, HV |
Hardness conversion | Rockwell, Vickers, Brinell, Leeb & Tensile 2 scales simultaneously |
Standardisation | N, ISO 6507, EN ISO 6506, ASTM E-10-08, ASTM E-92 |
Statistics | Total tests, max, min, average, range, standard deviation, all in real time after each test |
Control panel | Start test, stop test, dwell time, print, clear, menu operation for date, time, scale and load settings, language |
Firmware | German, English, French (standard) |
Memory | Large memory for testing results |
Data output | RS-232, Bi-Directional |
Loading mechanism | Fully automatic, closed loop, force feedback, loading, dwell, unloading |
Dwell time setting | Default 10 seconds, user defined 1 to 99 seconds |
Eyepiece microscope | Analogue or optional bright dual line filar |
Vertical capacity | 220mm (450mm XL model) |
Horizontal capacity | 135mm (250mm XL model) from center-line |
Humidity | 10% to 90% non condensing |
Machine weight | 130kg (160kg XL model) |
Power requirements | 100VAC to 240VAC, 50/60Hz, single phase |
Power consumption | 390W |