The Shimpo Panel Meter DT-5TXR panel meter with optional output is a value unit for speed and process time monitoring modules on any industrial floor. When connecting the Shimpo Panel Meter DT-5TXR with a compatible in-line sensor, the Shimpo Panel Meter DT-5TXR Panel Meter is versatile and reliable with selectable inputs. The Shimpo Panel Meter DT-5TXR is fully scalable by its three selectable modes allowing you to measure RPM/linear speed/rate, elapsed time and process time. Each panel meter accepts a variety of signal inputs from any sensor providing an NPN, contact, sine wave, or square wave such as pulse generators, proximity sensors, photoelectric sensors, magnetic sensors and NPN OC transistors.

Shimpo Panel Meter DT-5TXR with any variety of compatible sensor inputs desired, applications can range from timing of machining operation, rate of change monitoring such as on a conveyor, elapsed time of oven curing, chemical coating and timing of PCB and many more. The Shimpo Panel Meter DT-5TXR panel meter also accepts various output modules, enabling it to output data for analysis, record keeping or assist in controlling the process through a separate control device. Up to two modules can be accepted simultaneously, offering an enormous number of combinations and options.

 

Shimpo Panel Meter DT-5TXR Features:

  • Versatile with multiple sensor input capability in one unit: NPN open collector, contact and square or sine wave sensor inputs
  • Front cover protection eliminates accidental bumping of keypad to incorrect program
  • IP66 front cover protection keeps water out, enables usage in compatible plant wash-down operations
  • DC power source output to power compatible sensors saves money by eliminating need for separate power supply
  • Selectable decimal point enables higher resolution display potential 1/8 DIN size panel cut out permits easy, industry-standard mounting
  • Accepts up to two output modules allowing voltage, current, BCD, NPN & relay output combinations for control or remote process monitoring
  • Highly accurate (± 0.008% ± 1 digit) makes ideal for process control and analysis
  • Large 6 digit LED display plus two smaller 6 digit secondary displays allow easy viewing from greater distances
  • Scalable programming gives user the flexibility to set up and monitor virtually any process
  • Selectable update time allows operator to speed up/slow down display changes to facilitate process
  • Wide power range (85 – 264VAC, 50/60Hz) eliminates need for having to purchase and wire an additional power transformer. Low voltage models available

 

SPESIFIKASI Shimpo Panel Meter DT-5TXR

 Shimpo Panel Meter DT-5TXR Ordering Guide:

 
Shimpo DT-5TXR Panel Meter with Output Module Capability, Selectable inputs, 100-240 VAC Power
 Shimpo DT-5TXR-DC Panel Meter with Output Module Capability, Selectable inputs, 9-35 VDC Power
Shimpo DOP-BCDR BCD output module, 36 Pin Connection
Shimpo DOP-CPTR Relay output module, terminal block connection
Shimpo DOP-FVCR Analog output module (4-20mA & 0-1, 0-10, 1-5 VDC), 36-pin connection
Shimpo DOP-FVTR Analog output module (4-20mA & 0-1, 0-10, 1-5 VDC), terminal block connection
Shimpo DOP-RMTR Ratio input module, terminal block connection
Shimpo DOP-TRTR NPN open collector output module, terminal block connection

Note:

For Factory Assembled Panel Meter with Output Modules, Add Module to end of DT-5TXR Part and remove DOP. For two modules, only 1 36-Pin Module and 1 Terminal Block connection module can combine. Example: DT-5TXR-CPTR-FVC Panel Meter, 100-240VAC Power with Relay Output Terminal Module & 36-Pin Analog Output Module

 

 Shimpo Panel Meter DT-5TXR Accesories Ordering Guide:

 
Proximity Sensors BI2-S12 NPN (NO) sinking output 1.5 kHz frequency, LED indication, 6.5′ (2 m) cable, 0.08″ (2 mm) sensing distance, NEMA 6 (IP67) rating
DJ2-G NAMUR output, 3 kHz frequency, zero-sensing capability, 6.5′ (2 m) cable, 0.08″ (2mm) sensing distance, NEMA 6 (IP67) rating
MCS-3109 NPN (NO,NC) output, 300 Hz frequency, 0.32″ (8 mm) sensing distance, 6.5′ (2 m) cable, NEMA 6 (IP67) rating, for use in high vibration areas
SE-G Square wave output, 8 kHz frequency, LED indication, 18″ (0.46 m) cable, 0.04″ (1 mm) sensing distance
Retro-Reflective Photo Sensors MCS-625 Photo sensor with NPN sinking output, 250 Hz activating frequency, 10′ (3 m) cable 1″ to 3′ (25 to 914 mm) operating range
MCS-655 Photo sensor with NPN sinking output, 333 Hz activating frequency, LED status, 10′ (3 m) cable, NEMA 4 (IP65), 1″ to 3′ (25 to 914 mm) operating range for light or dark activation.
LS-S50MLR Laser sensor with NPN/PNP (NO,NC) outputs, 1.5 kHz frequency, LED indication, 6′ (1.8 m) with quick disconnect connection, NEMA 6 (IP67) rating
Rotary Pulse Generators RE1B-60F Rotary encoder in ABS housing with 60 ppr digital output, maximum speed 5000 rpm, 1.7 ft (0.5 m) cable
RE1B-600F Rotary encoder in ABS housing with 600 ppr digital output, maximum speed 5000 rpm, 1.7 ft (0.5 m) cable
RE1B-1000F Rotary encoder in ABS housing with 1000 ppr digital output, maximum speed 5000 rpm, 1.7 ft (0.5 m) cable
RE2B-30F Quadrature rotary encoder in ABS housing with Dual (90° out of phase) 30 ppr digital output, maximum speed: 5000 rpm, 1.7 ft (0.5 m) cable
RE2B-600F Quadrature rotary encoder in ABS housing with Dual (90° out of phase) 600 ppr digital output, maximum speed: 5000 rpm, 1.7 ft (0.5 m) cable
FPM-RE1B 12″ circumference wheel for use with RE1B and RE2B pulse generators
Magentic Pick-up Sensors MP-10 Sine wave output from change in magnetic to non-magnetic, change in voltage proportional to magnetic flux intensity over time, range of 0.01″ (0.25 mm) typical clearance, 10′ (3 m) cable
3030AN Sine wave output from change in magnetic to non-magnetic, change in voltage proportional to magnetic flux intensity over time, range of 0.01″ (0.25 mm) typical clearance, Amphenol connector
CABLE-3030 Optional cable for 3030AN
3070-XP12010 Sine wave output from change in magnetic to non-magnetic, change in voltage proportional to magnetic flux intensity over time, range of 0.01″ (0.25 mm) typical clearance, 10′ (3 m) cable Stainless steel housing, explosion-proof ATEX approved: II 2 GEExm II T3
Slot Type Sensor CM-SR21 For less dense materials that allows beam to penetrate through, NPN or PNP output with a 0.08″ (2 mm) gap range, NEMA 4x (IP65) housing.
CBL-75ANL Optional cable for CM-SR21 16.4′ (5 m)

 

Harga Shimpo Panel Meter DT-5TXR

Silahkan isi formulir di bawah ini untuk mendapatkan harga terbaik dari tim kami.

The Shimpo Panel Meter DT-5TXR panel meter with optional output is a value unit for speed and process time monitoring modules on any industrial floor. When connecting the Shimpo Panel Meter DT-5TXR with a compatible in-line sensor, the Shimpo Panel Meter DT-5TXR Panel Meter is versatile and reliable with selectable inputs. The Shimpo Panel Meter DT-5TXR is fully scalable by its three selectable modes allowing you to measure RPM/linear speed/rate, elapsed time and process time. Each panel meter accepts a variety of signal inputs from any sensor providing an NPN, contact, sine wave, or square wave such as pulse generators, proximity sensors, photoelectric sensors, magnetic sensors and NPN OC transistors.

Shimpo Panel Meter DT-5TXR with any variety of compatible sensor inputs desired, applications can range from timing of machining operation, rate of change monitoring such as on a conveyor, elapsed time of oven curing, chemical coating and timing of PCB and many more. The Shimpo Panel Meter DT-5TXR panel meter also accepts various output modules, enabling it to output data for analysis, record keeping or assist in controlling the process through a separate control device. Up to two modules can be accepted simultaneously, offering an enormous number of combinations and options.

 

Shimpo Panel Meter DT-5TXR Features:

 

">